基于電機(jī)驅(qū)動(dòng)技術(shù)的三工位隔離/接地開(kāi)關(guān)操作機(jī)構(gòu)設(shè)計(jì)

來(lái)源:電工電氣發(fā)布時(shí)間:2024-07-02 13:02瀏覽次數(shù):323

基于電機(jī)驅(qū)動(dòng)技術(shù)的三工位隔離/接地開(kāi)關(guān)操作機(jī)構(gòu)設(shè)計(jì)

楊春月1,2,呂敏1,2,方啟2,呂尋浩1,2,高延峰1,2,張濤鋒1,2,陳東1,2,陳蕾1,2
(1 河南平芝高壓開(kāi)關(guān)有限公司,河南 平頂山 467013;
2 河南平高電氣股份有限公司,河南 平頂山 467001)
 
    摘 要: 針對(duì)目前高壓隔離開(kāi)關(guān)在操作過(guò)程中存在的可控性差,難以實(shí)現(xiàn)動(dòng)觸頭的精準(zhǔn)控制,控制回路復(fù)雜,分合閘指令需要通過(guò)繼電器輸入,容易出現(xiàn)隔離開(kāi)關(guān)誤動(dòng)的問(wèn)題,提出了一種集成化、智能化、可強(qiáng)電輸入輸出、雙閉環(huán)精準(zhǔn)控制的隔離/接地開(kāi)關(guān)電機(jī)直驅(qū)操作機(jī)構(gòu)。該操作機(jī)構(gòu)根據(jù)隔離開(kāi)關(guān)動(dòng)觸頭運(yùn)動(dòng)曲線,通過(guò)對(duì)電機(jī)電流、速度、位置信號(hào)進(jìn)行采集,運(yùn)用 SVPWM 電壓矢量控制算法,實(shí)現(xiàn)對(duì)隔離/接地開(kāi)關(guān)運(yùn)動(dòng)過(guò)程的精準(zhǔn)控制。試驗(yàn)結(jié)果表明:該操作機(jī)構(gòu)從收到動(dòng)作信號(hào)到動(dòng)作結(jié)束時(shí)間短,啟動(dòng)后可在很短時(shí)間內(nèi)達(dá)到預(yù)設(shè)速度,整個(gè)動(dòng)作過(guò)程中機(jī)構(gòu)輸出穩(wěn)定、波動(dòng)小,有效提高了隔離/接地開(kāi)關(guān)的可靠性。
    關(guān)鍵詞: 電機(jī)驅(qū)動(dòng);高壓隔離/ 接地開(kāi)關(guān);操作機(jī)構(gòu);SVPWM 算法;伺服電機(jī);精準(zhǔn)控制
    中圖分類號(hào):TM564.1     文獻(xiàn)標(biāo)識(shí)碼:A     文章編號(hào):1007-3175(2024)06-0059-06
 
Design of the Operating Mechanism of the Three-Station Disconnecting/
Earthing Switch Based on Motor Drive Technology
 
YANG Chun-yue1,2, LYU Min1,2, FANG Qi2, LYU Xun-hao1,2, GAO Yan-feng1,2, ZHANG Tao-feng1,2, CHEN Dong1,2, CHEN Lei1,2
(1 Henan Pingzhi High-Voltage Switch Co., Ltd, Pingdingshan 467013, China;
2 Henan Pinggao Electric Co., Ltd, Pingdingshan 467001, China)
 
    Abstract: In view of the poor controllability of the current high-voltage disconnecting switch in the operation process, it is difficult to realize the precise control of the moving contact, the control loop is complex, and the opening and closing instructions need to be input through the relay, which is prone to the problem of misoperation of the disconnecting/earthing switch. In this paper, an integrated and intelligent,strong electrical input and output, double closed-loop precise control of disconnecting/earthing switch motor drive operating mechanism is proposed. According to the moving contact curve of the disconnecting/earthing switch, the operating mechanism collects the current, speed and position signals of the motor, and uses the SVPWM voltage vector control algorithm to realize the precise control of the movement process of the disconnecting/earthing switch. The test shows that the motor drive operating mechanism has a short time from receiving the action signal to the end of the action, and can reach the preset speed in a very short time after starting, and the output of the mechanism is stable and the fluctuation is small in the whole action process, which effectively improves the reliability of the disconnecting/earthing switch.
    Key words: motor drive; high-voltage disconnecting/earthing switch; operating mechanism; SVPWM algorithm; servo motor ; precise control
 
參考文獻(xiàn)
[1] 馬骎,馬龍. 高壓隔離開(kāi)關(guān)在電力系統(tǒng)的作用以及故障分析[J]. 科技資訊,2018,16(9) :38-39.
[2] 王艷利. 淺析高壓隔離開(kāi)關(guān)故障原因及檢修措施[J] .中國(guó)新技術(shù)新產(chǎn)品,2016,24(7) :86.
[3] 楊堃,李煒,宋杲,等.2013 年高壓開(kāi)關(guān)設(shè)備運(yùn)行分析[J]. 智能電網(wǎng),2014(6) :32-41.
[4] 吳志恒. 高壓 GIS 隔離開(kāi)關(guān)電機(jī)操動(dòng)機(jī)構(gòu)控制系統(tǒng)研究[D]. 沈陽(yáng):沈陽(yáng)工業(yè)大學(xué),2015.
[5] 董祥淵,段曉輝,王賽豪,等. 高壓開(kāi)關(guān)設(shè)備故障原因分析及處理方法[J]. 科技視界,2017,7(11) :61.
[6] 王建洲. 高壓斷路器與隔離開(kāi)關(guān)運(yùn)行異常及處理[J] .農(nóng)村電工,2021,29(9) :43-44.
[7] 陳富國(guó),何大偉,周瑞敏,等.550 kV 高壓隔離開(kāi)關(guān)電機(jī)驅(qū)動(dòng)智能控制系統(tǒng)[J] . 儀表技術(shù)與傳感器,2017,54(4) :78-82.
[8] 劉愛(ài)民,吳志恒,徐建源,等. 高壓隔離開(kāi)關(guān)電機(jī)操動(dòng)機(jī)構(gòu)控制系統(tǒng)[J] . 沈陽(yáng)工業(yè)大學(xué)學(xué)報(bào),2014,36(4) :361-366.
[9] 柏長(zhǎng)宇,錢凱,韓國(guó)輝,等. 高壓斷路器電機(jī)驅(qū)動(dòng)機(jī)構(gòu)數(shù)字控制技術(shù)研究[J] . 大連交通大學(xué)學(xué)報(bào),2020,41(5) :102-106.
[10] 王曉宇,林莘,徐建源,等. 高壓斷路器直線伺服電機(jī)操動(dòng)機(jī)構(gòu)及其動(dòng)觸頭運(yùn)動(dòng)控制的研究[C]//2008 年中國(guó)電機(jī)工程學(xué)會(huì)年會(huì)論文集,2008.
[11] 劉志遠(yuǎn),趙欣洋,陸洪建,等. 基于 IGBT 技術(shù)的隔離開(kāi)關(guān)智能操控系統(tǒng)設(shè)計(jì)[J]. 寧夏電力,2019(5) :22-29.
[12] 劉書吉,宋海龍,劉釗. 一起機(jī)械振動(dòng)導(dǎo)致高壓隔離開(kāi)關(guān)誤動(dòng)分析及改進(jìn)[J]. 寧夏電力,2018(5) :38-43.
[13] 姚衛(wèi)東,周劍峰,梁?jiǎn)⒑?750 kV 斷路器分合閘后隔離開(kāi)關(guān)誤動(dòng)作分析[J]. 青海電力,2012,31(2) :46-48.
[14] 任國(guó)康. 變電站隔離開(kāi)關(guān)誤動(dòng)隱患分析及處理——以寧夏石嘴山市某220 kV 變電站為例[J] . 北京工業(yè)職業(yè)技術(shù)學(xué)院學(xué)報(bào),2018,17(2):122-126.