動力UPS在熔體直接紡絲生產(chǎn)中的設(shè)計配置分析
宋江頌
(江蘇德力化纖有限公司,江蘇 宿遷 223800)
摘 要:由于設(shè)計配置及安全防護不當(dāng)?shù)仍?,動力UPS 在電網(wǎng)閃絡(luò)時不能完全給變頻器平穩(wěn)供電,保證其平穩(wěn)運行。以某20萬t/年熔體直接紡絲裝置為例,對動力UPS的主要設(shè)備的設(shè)計配置做了詳細說明,并分析了這些配置的合理性、必要性。經(jīng)在熔體直接紡絲生產(chǎn)實際應(yīng)用表明,這種配置的可靠性、安全性得到了檢驗,能夠長周期平穩(wěn)運行,性價比較好。
關(guān)鍵詞:動力UPS;聚酯;變頻器;蓄電池
中圖分類號:TM919 文獻標(biāo)識碼:B 文章編號:1007-3175(2017)11-0045-03
Analysis of Power Uninterrupted Power Supply Design Configuration in Melt Direct Spinning Production
SONG Jiang-song
(Jiangsu Deli Chemical Fiber Co., Ltd, Suqian 223800, China)
Abstract: Because of design configuration and improper safety protection, when the power grid produces flashover, the power uninterrupted power supply (UPS) can’t completely gave stable power supply for the inverter so as to ensure its smooth running. Taking certain 20 million tons per year melt direct spinning device for example, this paper elaborated on the design configuration of main equipment of power UPS and analyzed the rationality and necessity of these configuration. The practical application of melt direct spinning production shows that the reliability and safety are inspected with long period smooth running and better cost performance.
Key words: power uninterrupted power supply; polyester; inverter; storage battery
參考文獻
[1] 宋江頌. 帶動力UPS 電動機配電系統(tǒng)設(shè)計分析[J].低壓電器,2013(9):38-40 .
[2] GB/T 18332.1—2009 電動道路車輛用鉛酸蓄電池[S].
[3] 宋江頌. 長絲生產(chǎn)聯(lián)苯爐安全聯(lián)鎖回路的誤動作及解決辦法[J]. 化工自動化及儀表,2013,40(5):686-688.