摘 要:針對(duì)高壓隔離開(kāi)關(guān)改造或擴(kuò)建現(xiàn)場(chǎng),由于安全距離不夠所帶來(lái)的吊裝難題,分析了高壓隔離開(kāi)關(guān)的常用吊裝方法,結(jié)合改造過(guò)程中的實(shí)際情況,研制了一套高壓隔離開(kāi)關(guān)簡(jiǎn)易吊裝裝置。闡述了電氣部分和機(jī)械部分的設(shè)計(jì)過(guò)程,并通過(guò)了現(xiàn)場(chǎng)應(yīng)用驗(yàn)證,該裝置適用于GW7型、CR型、DR型、S3CDT型等高壓隔離開(kāi)關(guān)改造工程,具有功能強(qiáng)大、體積小、組裝方便、性能可靠等優(yōu)點(diǎn)。
關(guān)鍵詞:高壓隔離開(kāi)關(guān);吊裝裝置;安全距離;改造工程
中圖分類號(hào):TM564.1 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1007-3175(2016)02-0050-04


Development of Simple Hoisting Device for High Voltage Disconnector 

YI Yong-li, LIN Ning, CHEN Zhi, LIU Chong 
Wenzhou Power Supply Company, Wenzhou 325000, China 
 

Abstract: In allusion to the problems which caused by safe distance during the process of modifying and extension project in transformer substation, this paper analyzed the hoisting method of high voltage disconnector in common use. A set of simple hoisting device for high voltage disconnector was designed according to the practical situation in hoisting process. This paper expounded the design process of electrical and mechanical parts. The device could be used in the modification works of many high voltage disconnectors, such as GW7、CR、DR、S3CDT, with the advantages of powerful functions, small volume, easy assemble and reliable performance.
Key words: high voltage disconnector; hoisting device; safe distance; modification works


參考文獻(xiàn)
[1] 雷玉貴.變電檢修[M].北京:中國(guó)水利水電出版社,2006.
[2] 苑舜,崔文軍.高壓隔離開(kāi)關(guān)設(shè)計(jì)與改造[M].北京:中國(guó)電力出版社,2007.
[3] 黃道華,李奕宏,蘇東青.高壓隔離開(kāi)關(guān)的不停電吊裝裝置[J].電工技術(shù),2010(4):70-71.
[4] 楊帆.220kV變電所隔離開(kāi)關(guān)改造的安全措施[J].農(nóng)村電氣化,2008(1):22-24.
[5] 國(guó)家電網(wǎng)公司.國(guó)家電網(wǎng)公司電力安全工作規(guī)程(變電部分)[M].北京:中國(guó)電力出版社,2009.
[6] 龔文豪.220kV松北站AREVA隔離開(kāi)關(guān)安裝[J].上海電力,2007(1):81-83.
[7] 倪匯川,李傳江,朱德亮,王音音.GW4型隔離開(kāi)關(guān)安裝調(diào)試的一個(gè)典型問(wèn)題分析[J].安徽電力,2011,28(3):9-11.