漏電斷路器電弧能量影響因素分析
張建成
(山東省產(chǎn)品質(zhì)量檢驗(yàn)研究院,山東 濟(jì)南 250102)
摘 要:以漏電斷路器作為對(duì)象,來研究分析短路分?jǐn)喈a(chǎn)生的電弧問題,給出了電弧能量方程和電弧持續(xù)時(shí)間相關(guān)因素,通過改變短路電流、功率因數(shù)、合閘角度等條件,采用高速數(shù)據(jù)采集系統(tǒng)進(jìn)行數(shù)據(jù)收集,對(duì)短路分?jǐn)噙^程中的電弧能量進(jìn)行數(shù)據(jù)解析,為相關(guān)企業(yè)進(jìn)行允通能量驗(yàn)證時(shí)優(yōu)化試驗(yàn)流程提供了幫助。
關(guān)鍵詞:電弧;漏電斷路器;電弧能量;合閘角;數(shù)據(jù)采集系統(tǒng)
中圖分類號(hào):TM561 文獻(xiàn)標(biāo)識(shí)碼:B 文章編號(hào):1007-3175(2016)01-0049-04
Influencing Factors Analysis on Electric Arc Energy of Residual-Current Circuit Breaker
ZHANG Jian-cheng
(Shandong Product Quality Inspection Research Institute, Jinan 250102, China)
Abstract: Taking the residual-current circuit breaker as the object, this paper studied and analyzed the electric arc problems caused by short-circuit breaking, giving the electric arc energy equation and the relevant factors of electric arc time of duration. Via changing the conditions such as short-circuit current, power factor and closing angle, the high speed data acquisition system was adopted to carry out data analysis on electric arc energy in short-circuit breaking process, which provides help for optimal experiment flow when the relevant enterprise verifies let-through energy.
Key words: electric arc; residual-current circuit breaker; electric arc energy; closing angle; data acquisition system
參考文獻(xiàn)
[1] 莊磊,付真斌,趙良德. 智能電表負(fù)荷開關(guān)接觸電阻特性的試驗(yàn)研究[J]. 電測(cè)與儀表,2014(7):18-22.
[2] 蔣遠(yuǎn)東,劉顯強(qiáng),梁慶龍,李志雄,余燈. 電流傳感器在線檢測(cè)高壓開關(guān)柜局放的研究[ J ] . 電氣技術(shù),2013(12):69-72.
[3] GB 16917.1—2014 家用和類似用途的帶過電流保護(hù)的剩余電流動(dòng)作斷路器(RCBO)[S].
[4] 許志紅,蘇金州,林抒毅. 交流接觸器分?jǐn)噙^程電弧能量分析[C]// 第三屆電工產(chǎn)品可靠性與電接觸國(guó)際會(huì)議,2009:155-159.