特高壓直流故障對(duì)風(fēng)電場(chǎng)送出可靠性的影響及改進(jìn)措施

來(lái)源:電工電氣發(fā)布時(shí)間:2016-04-06 10:06 瀏覽次數(shù):15

特高壓直流故障對(duì)風(fēng)電場(chǎng)送出可靠性的影響及改進(jìn)措施 

王衡1,姚秀萍1,常喜強(qiáng)1,周專2 
(1 國(guó)網(wǎng)新疆電力調(diào)度控制中心,新疆 烏魯木齊 830000;
2 國(guó)網(wǎng)新疆電力公司經(jīng)濟(jì)技術(shù)研究院,新疆 烏魯木齊 830013)
 
 

摘 要: 介紹了風(fēng)電特性和特高壓直流故障對(duì)電網(wǎng)的影響,分析了特高壓直流故障對(duì)風(fēng)電送出可靠性的影響。通過(guò)對(duì)系統(tǒng)進(jìn)行模擬仿真,發(fā)現(xiàn)通過(guò)優(yōu)化直流無(wú)功控制系統(tǒng)與穩(wěn)控系統(tǒng)間的動(dòng)作配合等措施,對(duì)減小直流系統(tǒng)故障對(duì)系統(tǒng)電壓波動(dòng)及風(fēng)機(jī)脫網(wǎng)的影響有明顯的作用。
關(guān)鍵詞: 特高壓直流;風(fēng)電場(chǎng);電壓;脫網(wǎng);可靠性
中圖分類號(hào):TM614 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1007-3175(2014)05-0029-05


Impacts of Ultra High Voltage Direct Current Fault on Output Reliability of Wind Farm and Improvement Measures 

WANG Heng1, YAO Xiu-ping1, CHANG Xi-qiang1, ZHOU Zhuan2 
(1 Xinjiang Communication Center for Power Dispatching, Urumqi 83 0000, China;
2 State Grid Electric Power Company Xinjiang Institute of Economic Research Technology, Urumqi 830013, China)
 
 

Abstract: Introduction was made to the wind power characteristics and the impacts of ultra high voltage (UHV) direct current (DC) fault on the grid and analysis was made to the impact of UHV DC fault on the output reliability of wind farm. The system simulation shows that via optimizing action and collocation between the DC reactive control system and the stability control system etc measures, there are obvious effects on reducing the impact of DC fault on the system voltage fluctuation and the takeoff grid of winddriven generator.
         Key words: ultra high voltage direct current; wind farm; voltage; takeoff grid; reliability


參考文獻(xiàn)
[1] 李喜蘭,王大光,賓雪,等.近期風(fēng)電場(chǎng)接入福建電力系統(tǒng)探討[C]//2008中國(guó)電力系統(tǒng)保護(hù)與控制學(xué)術(shù)研討會(huì)論文集,2008:33-38.
[2] 吳義純,丁明. 風(fēng)電場(chǎng)可靠性評(píng)估[J]. 中國(guó)電力,2004,37(5):86-89.
[3] 許曉艷,石文輝,李巖春,等.風(fēng)電場(chǎng)集中接入對(duì)區(qū)域電網(wǎng)的影響分析[J].中國(guó)電力,2009,42(1):93-97.
[4] 遲永寧,王偉勝,劉燕華,等. 大型風(fēng)電場(chǎng)對(duì)電力系統(tǒng)暫態(tài)穩(wěn)定性的影響[J]. 電力系統(tǒng)自動(dòng)化,2006,30(15):10-14.