變電站母線電壓越限告警信息量問題的分析及處理
曹娜
(國網吳忠供電公司,寧夏 吳忠 751100)
摘 要:通過監(jiān)控信息量現狀分析,找出了造成變電站母線電壓越限告警信息量大的主要原因,針對性地提出了建立集中監(jiān)控專家處理系統(tǒng)、建立電壓越限預處理模型兩種解決方案,并通過對比確定了采用電壓越限預處理模型,方案實施效果表明,采用該模型后,降低了變電站母線電壓越限告警信息量,提高了監(jiān)控效率, 保證了電網安全可靠運行。
關鍵詞:監(jiān)控信息量;變電站;電壓越限;監(jiān)控效率
中圖分類號:TM63 文獻標識碼:A 文章編號:1007-3175(2016)06-0051-04
Analysis and Treatment of Out-Of-Limit Alarm Information
Amount of Bus Voltage in Substation
CAO Na
(State Grid Wuzhong Power Supply Company, Wuzhong 7511 00, China)
Abstract: After the status quo of monitoring information amount was analyzed, this paper found out the main reasons of out-of-limit alarm information amount of bus voltage in substation, raised two kinds of solutions about the centralized monitoring expert processing system and voltage out-oflimit pretreatment model, and determined the voltage out-of-limit pretreatment model via comparison. The plan implementation results show that after the model is used, the out-of-limit alarm information amount of bus voltage in substation is greatly reduced, which improves the monitoring efficiency and guarantees the safe and reliable operation of power grid.
Key words: monitoring information amount; substation; voltage out-of-limit; monitoring efficiency
參考文獻
[1] 袁建黨,易炳星,李軍,等. 精簡監(jiān)控系統(tǒng)遙測越限告警信號量[J]. 四川電力技術,2014,37(2):45-47.
[2] 黃朝圣,姚樹新,陳衛(wèi)澤. 淺談專家系統(tǒng)現狀與開發(fā)[J]. 信息安全與技術,2013,4(2):71-74.
[3] 黃偉. 變電站監(jiān)控信號告警在線處理專家系統(tǒng)[D]. 南京:南京郵電大學,2008.